[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]
- Fully self-contained flash point test module
- Ambient to 93 °C (200 °F)
- Conforms to the Tag test method requirements
- Automatic set up of test parameters
- Automatic heating control and flash detection
- Automatic test results and end of test audible warning
- Centigrade or Fahrenheit temperature display
- Automatic barometric correction
[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]
Temperature Range | Ambient to 93 °C (5 °C to 93 °C with optional cryostat) |
Bath | Liquid |
Heating | Hot Plate |
Post Test Cooling | Fan assisted or Circulating liquid / external cryostat. Requires Cooling Boost Accessory (34008-0) |
Post Test Cool-down Time (90°C to 50°C) | 40 minutes (Fan) 3 minutes (external cryostat) |
Ignitor | Quick-fit coaxial gas jet / electric hot wire, user selectable (Electric hot wire pilot light for gas jet) |
Temperature Probes | Class A platinum resistance thermometers |
Flash Detection | Thermocouple |
Gas Supply (gas jet ignitor) | Laboratory gas, 3 kPa (0.44 psi) maximum pressure |
Cooling Supply | Water (5 °C and above) Water / Ethylene Glycol 50/50 (below 5 °C) 125kPa (18psi) maximum pressure |
[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Seta Multiflash Tag Flash Point Module” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F34400-0_Multiflash_Tag.pdf||target:%20_blank|” position=”text-left” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]
ASTM E502 | Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods |
ASTM D56 | Standard test method for flash point by Tag closed cup tester |
ASTM D3934 | Flash/No Flash Test-Equilibrium Method by the Closed-Cup Apparatus |
ASTM D3941 | Flash Point by the Equilibrium method with Closed Cup apparatus |
ISO 1516 | Flash Test Using The Cup of Any Standard Closed Cup Apparatus |
ISO 1523 | Flash Test Using The Cup of Any Standard Closed Cup Apparatus |
IP 491 | Determination of flash/no flash – Closed cup equilibrium method |
IP 492 | Determination of flash point – Closed cup equilibrium method |
[/vc_column_text][/vc_tta_section][/vc_tta_tour][/vc_column][/vc_row]