Warning: Undefined array key "options" in /home2/bptajhiz/domains/bptajhiz.com/public_html/wp-content/plugins/elementor-pro/modules/theme-builder/widgets/site-logo.php on line 192 Setaflash Series 8 ActiveCool Flash Point Tester - Gas Ignitor and Corrosion Resisting Cup - BPtajhiz
, , , , , ,

Setaflash Series 8 ActiveCool Flash Point Tester – Gas Ignitor and Corrosion Resisting Cup

Company: Stanhope-Seta

Methods:ASTM D3278, ASTM D3828, ASTM D7236, ASTM D8174, ASTM E502, BS EN ISO 3679, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, IP 523, IP 524, IP 534, UN Class 3 Non-viscous Flammable Liquids

The Setaflash Series 8 ActiveCool is an automated closed cup flash point tester with a temperature range of 10 to 130 °C (50 to 266 °F). The temperature range can extend down to -20 °C (-4 °F) if you connect the flash point tester to suitable chilled water supply.

[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]

Small sample size, 2 or 4 ml
Gas Ignitor
Automatic dipping and flash detection
ActiveCool electronic Peltier cooling
64 Test memory & RS232 interface
°C or °F temperature display

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]

ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
CLP Regulations EC No 1272/2008 European Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures
BS EN ISO 3679, BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products
UN Class 3 Non-viscous Flammable Liquids Small Scale Flash Point Testing
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
EPA 1020 A & B Setaflash Closed-Cup Method for determining ignitability
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Setaflash Series 8 ActiveCool Flash Point Tester – Gas Ignitor and Corrosion Resisting Cup” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F82000-0_Series_8.pdf||target:%20_blank|” position=”text-left” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][vc_raw_html]JTNDZGl2JTIwaWQlM0QlMjIxNTQ2MTU4MDkyMTExNDI5MiUyMiUzRSUzQ3NjcmlwdCUyMHR5cGUlM0QlMjJ0ZXh0JTJGSmF2YVNjcmlwdCUyMiUyMHNyYyUzRCUyMmh0dHBzJTNBJTJGJTJGd3d3LmFwYXJhdC5jb20lMkZlbWJlZCUyRlc2RGRJJTNGZGF0YSU1QnJuZGRpdiU1RCUzRDE1NDYxNTgwOTIxMTE0MjkyJTI2ZGF0YSU1QnJlc3BvbnNpdmUlNUQlM0R5ZXMlMjIlM0UlM0MlMkZzY3JpcHQlM0UlM0MlMkZkaXYlM0U=[/vc_raw_html][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]

ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
CLP Regulations EC No 1272/2008 European Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures
BS EN ISO 3679, BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products
UN Class 3 Non-viscous Flammable Liquids Small Scale Flash Point Testing
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
EPA 1020 A & B Setaflash Closed-Cup Method for determining ignitability
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester

[/vc_column_text][/vc_tta_section][/vc_tta_tour][/vc_column][/vc_row]

ASTM

, , , ,

BS EN ISO

BS

EPA

IP

, ,

Standard Metod

, , , ,

Scroll to Top