[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]
- Flash / No Flash & Ramp modes
- Flash point test in less than 2 minutes
- Small sample size – 2 or 4 ml
- Automatic flash detection
- Automatic barometric correction
- Electronic peltier cooling
- USB port and result storage
- Portable operation
[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]
Temperature Range | 10 to 135 °C |
Cup Material | Corrosion Resisting Steel Insert |
Test Modes | Rapid Equilibrium and Ramp |
Sample Size | 2 ml for flash points up to 100 °C 4 ml for flash points above 100 °C |
Test Duration | 1 minute below 100 °C, 2 minutes above 100 °C, or user determined 1 to 99 minutes |
Ramp Rate | 2 °C/min ramp |
Heating and Cooling System | Peltier Cell |
Power | 200 W (maximum) |
Voltage | 100/240 V, 50/60 Hz (switchable) 12 Vdc with optional power adaptor |
Gas Supply | Laboratory gas, 3 kPa (0.44 psi) maximum pressure or Butane from optional Portable Gas Tank 13667-0 |
[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Setaflash Series 3 ActiveCool Flash Point Tester – corrosion resistant cup” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F30000-2_Series_3.pdf|||” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][vc_raw_html]JTNDZGl2JTIwaWQlM0QlMjIxNTQ1ODk1NjY0OTU0MjE3MSUyMiUzRSUzQ3NjcmlwdCUyMHR5cGUlM0QlMjJ0ZXh0JTJGSmF2YVNjcmlwdCUyMiUyMHNyYyUzRCUyMmh0dHBzJTNBJTJGJTJGd3d3LmFwYXJhdC5jb20lMkZlbWJlZCUyRlNkbVZHJTNGZGF0YSU1QnJuZGRpdiU1RCUzRDE1NDU4OTU2NjQ5NTQyMTcxJTI2ZGF0YSU1QnJlc3BvbnNpdmUlNUQlM0R5ZXMlMjIlM0UlM0MlMkZzY3JpcHQlM0UlM0MlMkZkaXYlM0U=[/vc_raw_html][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]applaction note[/vc_column_text][/vc_column_inner][vc_column_inner width=”2/3″][button text=”dowload” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FProfiles%2FProduct_Profile.pdf||target:%20_blank|” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]
ASTM D7236 | Flash Point by Small Scale Closed Cup Ramp Method |
IP 534 | Flash Point by Small Scale Closed Cup Ramp Method |
BS EN ISO 3679, BS 2000-523 | Determination of flash no-flash and flash point. Rapid equilibrium closed cup method |
ASTM D8174 | Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester |
ASTM D3278 | Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products |
ISO 3680 (Obs) | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
ASTM E502 | Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods |
IP 523 | Determination of flash point. Rapid equilibrium closed cup method |
IP 524 | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
EPA 1020 A & B | Setaflash Closed-Cup Method for determining ignitability |
ASTM D3828 | Standard Test Methods for Flash Point by Small Scale Closed Tester |
[/vc_column_text][/vc_tta_section][/vc_tta_tour][/vc_column][/vc_row]