Warning: Undefined array key "options" in /home2/bptajhiz/domains/bptajhiz.com/public_html/wp-content/plugins/elementor-pro/modules/theme-builder/widgets/site-logo.php on line 192 Setaflash Series 3 ActiveCool Flash Point Tester - corrosion resistant cup - BPtajhiz
, , , , , ,

Setaflash Series 3 ActiveCool Flash Point Tester – corrosion resistant cup

Company: Stanhope-Seta

Methods:ASTM D3278, ASTM D3828, ASTM D7236, ASTM D8174, ASTM E502, BS EN ISO 3679, BS 2000-523, EPA 1020 A & B, IP 523, IP 524, IP 534, ISO 3680 (Obs)

Setaflash Series 3 Active Cool provides fast and reliable flash point results and requires minimum operator expertise. It has been designed to rapidly and efficiently carry out Flash / No Flash tests to determine the flash point of liquids and semi-solids in the 10 to 135 °C temperature range.

[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]

  • Flash / No Flash & Ramp modes
  • Flash point test in less than 2 minutes
  • Small sample size – 2 or 4 ml
  • Automatic flash detection
  • Automatic barometric correction
  • Electronic peltier cooling
  • USB port and result storage
  • Portable operation

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]

Temperature Range 10 to 135 °C
Cup Material Corrosion Resisting Steel Insert
Test Modes Rapid Equilibrium and Ramp
Sample Size 2 ml for flash points up to 100 °C 4 ml for flash points above 100 °C
Test Duration 1 minute below 100 °C, 2 minutes above 100 °C, or user determined 1 to 99 minutes
Ramp Rate 2 °C/min ramp
Heating and Cooling System Peltier Cell
Power 200 W (maximum)
Voltage 100/240 V, 50/60 Hz (switchable) 12 Vdc with optional power adaptor
Gas Supply Laboratory gas, 3 kPa (0.44 psi) maximum pressure or Butane from optional Portable Gas Tank 13667-0

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Setaflash Series 3 ActiveCool Flash Point Tester – corrosion resistant cup” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F30000-2_Series_3.pdf|||” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][vc_raw_html]JTNDZGl2JTIwaWQlM0QlMjIxNTQ1ODk1NjY0OTU0MjE3MSUyMiUzRSUzQ3NjcmlwdCUyMHR5cGUlM0QlMjJ0ZXh0JTJGSmF2YVNjcmlwdCUyMiUyMHNyYyUzRCUyMmh0dHBzJTNBJTJGJTJGd3d3LmFwYXJhdC5jb20lMkZlbWJlZCUyRlNkbVZHJTNGZGF0YSU1QnJuZGRpdiU1RCUzRDE1NDU4OTU2NjQ5NTQyMTcxJTI2ZGF0YSU1QnJlc3BvbnNpdmUlNUQlM0R5ZXMlMjIlM0UlM0MlMkZzY3JpcHQlM0UlM0MlMkZkaXYlM0U=[/vc_raw_html][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]applaction note[/vc_column_text][/vc_column_inner][vc_column_inner width=”2/3″][button text=”dowload” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FProfiles%2FProduct_Profile.pdf||target:%20_blank|” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]

ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
BS EN ISO 3679, BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products
ISO 3680 (Obs) Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
EPA 1020 A & B Setaflash Closed-Cup Method for determining ignitability
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester

[/vc_column_text][/vc_tta_section][/vc_tta_tour][/vc_column][/vc_row]

Standard Metod

, , , , ,

ASTM

, , , ,

IP

, ,

BS

BS EN ISO

ISO

Scroll to Top