Warning: Undefined array key "options" in /home2/bptajhiz/domains/bptajhiz.com/public_html/wp-content/plugins/elementor-pro/modules/theme-builder/widgets/site-logo.php on line 192 Setaflash Series 3 Plus Flash Point Tester - BPtajhiz
, , , , , ,

Setaflash Series 3 Plus Flash Point Tester

Company: Stanhope-Seta

Methods:STM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS EN ISO 3679, BS 2000-523, IP 523, IP 524, IP 534, ISO 3680 (Obs)

Setaflash Series 3 closed cup flash point tester provides fast and reliable flash point results with the additional feature of an automatic ‘Ramp’ mode. The temperature ramp mode is ideally suited for unknown samples and allows rapid determination of the flash point of a sample in accordance with ASTM D7236 and IP 534 standards. The closed cup is heated at a rate of 2 °C per minute from the starting temperature. An audible prompt sounds every 1 °C rise up to 100 °C, to carry out a flash test, then every 2 °C rise over 100 °C.

[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]

Ambient to 300 °C
Flash point test in less than 2 minutes
Small sample size – 2 or 4 ml
Flash/no Flash or Ramp mode
Automatic flash detection
Automatic barometric pressure correction
USB port & results storage
Portable operation

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]

Test modes Expected flash or search
Ignition system Electric hot-wire or gas flame
Flash detection Thermal
Cooling Forced air (integral fan)
Heating rate Fast heating mode (>10°C/min) and standard rate 5.50C/min, 3°C/min, 1.3°C/min, 1°C/min
Calibration Calibration dates/data stored to memory, easy retrieval and password protected
Application range Ambient to +5°C to +400°C
Sample temperature PT 100 stainless steel probe
Units of temperature °C or °F (user selectable
Barometric pressure correction Automatic correction with built-in pressure sensor
Information Real-time display on screen of test progress and results
Internal memory – parameters 30 programmable test profiles, sample ID’s, operator names and test methods
Internal memory – results In excess of 2000 test results
Fire detection Thermal with integral CO2 fire extinguisher (factory fitted option)
External fire alarm relay contact 240Vac max, 1A max resistive. External warning: 12V dc signal output
Gas type Butane, propane or natural gas source

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Setaflash Series 3 Plus Flash Point Tester” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F30000-2_Series_3.pdf||target:%20_blank|” position=”text-left” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][vc_raw_html]JTNDZGl2JTIwaWQlM0QlMjIxNTQ1ODk1NjY0OTU0MjE3MSUyMiUzRSUzQ3NjcmlwdCUyMHR5cGUlM0QlMjJ0ZXh0JTJGSmF2YVNjcmlwdCUyMiUyMHNyYyUzRCUyMmh0dHBzJTNBJTJGJTJGd3d3LmFwYXJhdC5jb20lMkZlbWJlZCUyRlNkbVZHJTNGZGF0YSU1QnJuZGRpdiU1RCUzRDE1NDU4OTU2NjQ5NTQyMTcxJTI2ZGF0YSU1QnJlc3BvbnNpdmUlNUQlM0R5ZXMlMjIlM0UlM0MlMkZzY3JpcHQlM0UlM0MlMkZkaXYlM0U=[/vc_raw_html][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][vc_row_inner][vc_column_inner width=”1/3″][vc_column_text]applaction note[/vc_column_text][/vc_column_inner][vc_column_inner width=”2/3″][button text=”dowload” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FProfiles%2FProduct_Profile.pdf||target:%20_blank|” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]

ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
BS EN ISO 3679, BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method.
ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products
ISO 3680 (Obs) Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester