Warning: Undefined array key "options" in /home2/bptajhiz/domains/bptajhiz.com/public_html/wp-content/plugins/elementor-pro/modules/theme-builder/widgets/site-logo.php on line 192 Setaflash Series 8 Closed Cup Flash Point Tester - High Temperature - BPtajhiz
, , , , , ,

Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature

Company: Stanhope-Seta

Methods:ASTM D3278, ASTM D3828, ASTM D7236, ASTM D8174, ASTM E502, BS EN ISO 3679, BS 2000-523, IP 523, IP 524, IP 534

The Setaflash Series 8 is an automated closed cup flash point tester with a temperature range of ambient to 300 °C (ambient to 572 °F). The instrument uses an electric hot wire ignitor.

[vc_row][vc_column][vc_tta_tour style=”modern” color=”sky” spacing=”2″ gap=”1″ active_section=”1″][vc_tta_section title=”Features” tab_id=”1545581598179-660fe406-aaa8″][vc_column_text]

  • Small sample size, 2 or 4 ml
  • Electric ignitor
  • Automatic dipping and flash detection
  • 64 Test memory & RS232 interface
  • °C or °F temperature display
  • Forced air cooling for rapid test cycling

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Technical Specifications” tab_id=”1545581598190-53870fe7-af5c”][vc_column_text]

Temperature Range Ambient to 300 °C (Ambient to 572 °F)
Sample Size 2 or 4 ml according to method
Ignitor Electrical Hot Wire
Test duration, Rapid Equilibrium Mode 1 minute below 100 °C, 2 minutes above 100 °C,
Test duration, Ramp Mode Typically 7 minutes
Sample Cup Material Aluminium
Heating/Cooling Method Ceramic Pad, Forced Air (post-test cooldown)

[/vc_column_text][/vc_tta_section][vc_tta_section title=”Data Sheet, Brochures” tab_id=”1545581600047-046fcad2-e63c”][button text=”Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature” link=”url:http%3A%2F%2Fwww.stanhope-seta.co.uk%2FSSL_Downloads%2FBrochures%2F82000-0_Series_8.pdf||target:%20_blank|” position=”text-left” show_icon=”had_icon” icon_fontawesome=”fa fa-download”][/vc_tta_section][vc_tta_section title=”video” tab_id=”1545681154224-d7fe74e7-0830″][vc_raw_html]JTNDZGl2JTIwaWQlM0QlMjIxNTQ2MTU0Nzg5MzcxNzcwNiUyMiUzRSUzQ3NjcmlwdCUyMHR5cGUlM0QlMjJ0ZXh0JTJGSmF2YVNjcmlwdCUyMiUyMHNyYyUzRCUyMmh0dHBzJTNBJTJGJTJGd3d3LmFwYXJhdC5jb20lMkZlbWJlZCUyRlc2RGRJJTNGZGF0YSU1QnJuZGRpdiU1RCUzRDE1NDYxNTQ3ODkzNzE3NzA2JTI2ZGF0YSU1QnJlc3BvbnNpdmUlNUQlM0R5ZXMlMjIlM0UlM0MlMkZzY3JpcHQlM0UlM0MlMkZkaXYlM0U=[/vc_raw_html][/vc_tta_section][vc_tta_section title=”Application Notes” tab_id=”1545581611988-20ede119-6ff3″][/vc_tta_section][vc_tta_section title=”Standard Method” tab_id=”1545581615091-5b2aac71-0552″][vc_column_text]

ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
BS EN ISO 3679, BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus – paints, enamels, lacquers, varnishes, and related products
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester

[/vc_column_text][/vc_tta_section][/vc_tta_tour][/vc_column][/vc_row]

ASTM

, , , ,

BS EN ISO

BS

IP

, ,

Standard Metod

, , ,

Scroll to Top